Cleared Traditional

K001178 - CEDIA DAU 6-ACETYLMORPHINE ASSAY

K001178 is an FDA 510(k) clearance for CEDIA DAU 6-ACETYLMORPHINE ASSAY, manufactured by Microgenics Corp.. The device is a Class 2 Toxicology device with product code DJG cleared through the Traditional 510(k) pathway after a 59-day FDA review.

Download Printable Device Report (PDF) Official FDA 510(k) Summary (PDF)
Optimized for regulatory review, auditing and printing
Jun 2000
Decision
59d
Days
Class 2
Risk

K001178 is an FDA 510(k) clearance for the CEDIA DAU 6-ACETYLMORPHINE ASSAY. Classified as Enzyme Immunoassay, Opiates (product code DJG), Class II - Special Controls.

Submitted by Microgenics Corp. (Fremont Blvd., US). The FDA issued a Cleared decision on June 9, 2000 after a review of 59 days - a notably fast clearance cycle.

This device falls under the Toxicology FDA review panel, regulated under 21 CFR 862.3650 - the FDA toxicology device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

FDA 510(k) Submission Details - K001178

510(k) Number K001178 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received April 11, 2000
Decision Date June 09, 2000
Days to Decision 59 days
Submission Type Traditional
Review Panel Toxicology (TX)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
28d faster than avg
Panel avg: 87d · This submission: 59d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

DJG Device Classification - Class 2, Special Controls

Product Code DJG Enzyme Immunoassay, Opiates
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 862.3650
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Toxicology devices follow this clearance model.

Regulatory Peers - DJG Enzyme Immunoassay, Opiates

All 214
Devices cleared under the same product code (DJG) and FDA review panel - the closest regulatory comparables to K001178.
PSYCHEMEDICS ANALYSIS OF MORPHINE IN HAIR
K000851 · Psychemedics Corp. · Dec 2000
URINE OPIATES (OPI) SCREEN FLEX REAGENT CARTRIDGE, CATALOG NO. DF93A
K003209 · Dade Behring, Inc. · Dec 2000
BRANAN MEDICAL CORPORATION MONITECT MORPHINE 2000 DRUG SCREEN TEST
K002268 · Branan Medical Corporation · Nov 2000
URINE OPIATES (OPI) SCREEN FLEX REAGENT CARTRIDGE, CATALOG NO. DF 90A
K000464 · Dade Behring, Inc. · Apr 2000
SCREENERS OPIATES TEST DRUGSCREEN DIP OPIATES TEST
K000273 · Drug Detection Devices, Ltd. · Apr 2000
RADID DRUG SCREEN 5-PANEL TEST