Cleared Special

K013033 - MODIFICATION TO: HL168W TOUCH SCREEN

K013033 is an FDA 510(k) clearance for MODIFICATION TO: HL168W TOUCH SCREEN, manufactured by Health & Life Co., Ltd.. The device is a Class 2 Cardiovascular device with product code DXN cleared through the Special 510(k) pathway after a 43-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Oct 2001
Decision
43d
Days
Class 2
Risk

K013033 is an FDA 510(k) clearance for the MODIFICATION TO: HL168W TOUCH SCREEN. Classified as System, Measurement, Blood-pressure, Non-invasive (product code DXN), Class II - Special Controls.

Submitted by Health & Life Co., Ltd. (Taipei Hsien, TW). The FDA issued a Cleared decision on October 23, 2001 after a review of 43 days - a notably fast clearance cycle.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.1130 - the FDA cardiovascular device oversight framework. As a Special 510(k), this submission covers a manufacturer modification to an existing cleared device rather than a new device introduction.

Device pattern: Iterative device modification. Low regulatory complexity profile. This Special 510(k) clearance confirms that the manufacturer's modifications remained within the established regulatory envelope of the original cleared device.

FDA 510(k) Submission Details - K013033

510(k) Number K013033 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received September 10, 2001
Decision Date October 23, 2001
Days to Decision 43 days
Submission Type Special
Review Panel Cardiovascular (CV)
Summary Statement
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
82d faster than avg
Panel avg: 125d · This submission: 43d
Pathway characteristics
Modification to existing cleared device.

DXN Device Classification - Class 2, Special Controls

Product Code DXN System, Measurement, Blood-pressure, Non-invasive
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.1130
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - DXN System, Measurement, Blood-pressure, Non-invasive

All 1225
Devices cleared under the same product code (DXN) and FDA review panel - the closest regulatory comparables to K013033.
DYNAPULSE 500G (DP500G) BLLOD PRESSURE MONITORING SYSTEM
K012498 · Pulse Metric, Inc. · Nov 2001
BPTRU AUTOMATED NON-INVASIVE BLOOD PRESSURE MONITOR, MODEL BPM-100
K012636 · Vsm Technology, Inc. · Oct 2001
TELEPRESS III BLOOD PRESSURE MONITOR, MODEL TPIII
K011058 · Meridian Medical Technologies , Ltd. · Oct 2001
MODIFICATION TO:HL168D BLOOD PRESSURE MONITOR
K012310 · Health & Life Co., Ltd. · Aug 2001
FULL AUTO WRIST DIGITAL BLOOD PRESSURE MONITOR, MODEL SE-312
K012054 · Sein Electronics Co., Ltd. · Aug 2001
BRAUN PRECISION SENSOR PRO, MODEL BP 2590
K012035 · Braun GmbH · Jul 2001