Cleared Traditional

K020779 - PROXIMATE AND ENDOPATH LINEAR CUTTERS AND STAPLERS

K020779 is an FDA 510(k) clearance for PROXIMATE AND ENDOPATH LINEAR CUTTERS A..., manufactured by Ethicon Endo-Surgery, Inc.. The device is a Class 2 General & Plastic Surgery device with product code GDW cleared through the Traditional 510(k) pathway after a 86-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Jun 2002
Decision
86d
Days
Class 2
Risk

K020779 is an FDA 510(k) clearance for the PROXIMATE AND ENDOPATH LINEAR CUTTERS AND STAPLERS. Classified as Staple, Implantable (product code GDW), Class II - Special Controls.

Submitted by Ethicon Endo-Surgery, Inc. (Cincinnati, US). The FDA issued a Cleared decision on June 5, 2002 after a review of 86 days - a notably fast clearance cycle.

This device falls under the General & Plastic Surgery FDA review panel, regulated under 21 CFR 878.4750 - the FDA general and plastic surgery device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all Ethicon Endo-Surgery, Inc. devices

FDA 510(k) Submission Details - K020779

510(k) Number K020779 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received March 11, 2002
Decision Date June 05, 2002
Days to Decision 86 days
Submission Type Traditional
Review Panel General & Plastic Surgery (SU)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
29d faster than avg
Panel avg: 115d · This submission: 86d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

GDW Device Classification - Class 2, Special Controls

Product Code GDW Staple, Implantable
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 878.4750
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most General & Plastic Surgery devices follow this clearance model.

Regulatory Peers - GDW Staple, Implantable

All 184
Devices cleared under the same product code (GDW) and FDA review panel - the closest regulatory comparables to K020779.
SURGASSIST RIGHT ANGLE LINEAR CUTTER DLU 30MM, 45MM & 60MM - VASCULAR WITH RELOADS, MODELS RALC30V, RALC45V & RALC60V
K022313 · Power Medical Interventions, Inc. · Dec 2002
AUTO SUTURE PREMIUM PLUS CEEA DISPOSABLE STAPLER
K020804 · United States Surgical, A Division of Tyco Healthc · Nov 2002
SURGASSIST RIGHT ANGLE LINEAR CUTTER 30MM, 45MM & 60MM, MODELS RALC30, RALC45 & RALC60
K021701 · Power Medical Interventions, Inc. · Jun 2002
SURGASSIST FLEXSHAFT 2, MODEL FS2 14
K021249 · Power Medical Interventions, Inc. · May 2002
SURGASSIST SYSTEM STRAIGHT LINEAR CUTTER DIGITAL LOADING UNIT, 55MM, 30MM WITH BLUE AND GREEN RELOAD CARTRIDGES
K020719 · Power Medical Interventions, Inc. · May 2002
SURGASSIST SYSTEM
K020343 · Power Medical Interventions, Inc. · Apr 2002