Cleared Traditional

WILSON-COOK CELIAC PLEXUS NEUROLYSIS NEEDLE (K030618) - FDA 510(k) Clearance

Class II Anesthesiology device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
May 2003
Decision
90d
Days
Class 2
Risk

K030618 is an FDA 510(k) clearance for the WILSON-COOK CELIAC PLEXUS NEUROLYSIS NEEDLE. Classified as Needle, Conduction, Anesthetic (w/wo Introducer) (product code BSP), Class II - Special Controls.

Submitted by Wilson-Cook Medical, Inc. (Winston-Salem, US). The FDA issued a Cleared decision on May 27, 2003 after a review of 90 days - within the typical 510(k) review window.

This device falls under the Anesthesiology FDA review panel, regulated under 21 CFR 868.5150 - the FDA anesthesiology and respiratory device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Standard predicate reliance. This clearance follows a standard predicate-based equivalence path within the Anesthesiology review framework, consistent with the majority of Class II 510(k) submissions.

View all Wilson-Cook Medical, Inc. devices

Submission Details

510(k) Number K030618 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received February 26, 2003
Decision Date May 27, 2003
Days to Decision 90 days
Submission Type Traditional
Review Panel Anesthesiology (AN)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
50d faster than avg
Panel avg: 140d · This submission: 90d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code BSP Needle, Conduction, Anesthetic (w/wo Introducer)
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 868.5150
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Anesthesiology devices follow this clearance model.

Regulatory Peers - BSP Needle, Conduction, Anesthetic (w/wo Introducer)

All 43
Devices cleared under the same product code (BSP) and FDA review panel - the closest regulatory comparables to K030618.
CONTIPLEX D CONTINUOUS NERVE BLOCK SET, MODEL 331687, 331686, 331685, 331680
K100241 · B.Braun Medical, Inc. · Apr 2010
FOCUS ( TM) ECHOGENIC NERVE STIMULATING NEEDLE
K093209 · Cook, Inc. · Feb 2010
BD SPINAL NEEDLE, MODELS: 405081, 405235, 405236, 405237
K081446 · Becton, Dickinson & CO · Jul 2008
PERIFIX SAFETY EPIDURAL NEEDLES
K013610 · B.Braun Medical, Inc. · Jan 2002
CLEAR HUB SPINAL NEEDLE, 18, 20, 22, 25 GA.
K951949 · Baxter Healthcare Corp · Aug 1995
MONOJECT WHITACRE POINT SPINAL NEEDLE (27G X 3 1/2)
K951312 · Sherwood Medical Co. · May 1995