Jan 2004
Decision
36d
Days
Class 2
Risk

K033908 is an FDA 510(k) clearance for the N HIGH SENSITIVITY CRP. Classified as Cardiac C-reactive Protein, Antigen, Antiserum, And Control (product code NQD), Class II - Special Controls.

Submitted by Dade Behring, Inc. (Newark, US). The FDA issued a Cleared decision on January 22, 2004 after a review of 36 days - a notably fast clearance cycle.

This device falls under the Chemistry FDA review panel, regulated under 21 CFR 866.5270 - the FDA in vitro diagnostics and chemistry framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all Dade Behring, Inc. devices

Submission Details

510(k) Number K033908 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received December 17, 2003
Decision Date January 22, 2004
Days to Decision 36 days
Submission Type Traditional
Review Panel Chemistry (CH)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
52d faster than avg
Panel avg: 88d · This submission: 36d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code NQD Cardiac C-reactive Protein, Antigen, Antiserum, And Control
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 866.5270
Definition In Vitro Diagnostic Test To Measure C-reactive Protein For The Purpose Of Making Cardiac Risk Assessments.
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Chemistry devices follow this clearance model.

Regulatory Peers - NQD Cardiac C-reactive Protein, Antigen, Antiserum, And Control

All 16
Devices cleared under the same product code (NQD) and FDA review panel - the closest regulatory comparables to K033908.
TINA-QUANT CRP (LATEX) HS TEST SYSTEM (C-REACTIVE PROTEIN (LATEX) HIGH SENSITIVE)
K042485 · Roche Diagnostics Corp. · Oct 2004
VITROS CHEMISTRY PRODUCTS HSCRP REAGENT, VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 17, VITROS CHEMISTRY PRODUCTS FS
K041799 · Ortho-Clinical Diagnostics, Inc. · Aug 2004
OLYMPUS CRP LATEX IMMUNOTURBIDIMETRIC REAGENT
K041668 · Olympus America, Inc. · Aug 2004