Cleared Traditional

K061305 - MEDICAL DISPLAY, MDC1900-1LG (1LR)

K061305 is an FDA 510(k) clearance for MEDICAL DISPLAY, manufactured by Chi Lin Technology Co., Ltd.. The device is a Class 2 Radiology device with product code LLZ cleared through the Traditional 510(k) pathway after a 15-day FDA review.

Download Printable Device Report (PDF) Official FDA 510(k) Summary (PDF)
Optimized for regulatory review, auditing and printing
May 2006
Decision
15d
Days
Class 2
Risk

K061305 is an FDA 510(k) clearance for the MEDICAL DISPLAY, MDC1900-1LG (1LR). Classified as System, Image Processing, Radiological within the LLZ classification (a category encompassing advanced image processing and PACS-adjacent software), Class II - Special Controls.

Submitted by Chi Lin Technology Co., Ltd. (Jen Te Hsian, Tainan County, TW). The FDA issued a Cleared decision on May 25, 2006 after a review of 15 days - a notably fast clearance cycle.

This device falls under the Radiology FDA review panel, regulated under 21 CFR 892.2050 - the FDA radiology and imaging software oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Incremental AI imaging tool. Moderate equivalence dependency. Overall, this clearance reflects a predicate-aligned approval typical of modern AI radiology extensions - not a novel clinical breakthrough, but a validated iteration within an established regulatory category.

FDA 510(k) Submission Details - K061305

510(k) Number K061305 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received May 10, 2006
Decision Date May 25, 2006
Days to Decision 15 days
Submission Type Traditional
Review Panel Radiology (RA)
Summary Summary PDF
Third-party Review Yes - reviewed by an FDA-accredited third party
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
92d faster than avg
Panel avg: 107d · This submission: 15d
Pathway characteristics
Predicate-based equivalence. No clinical trials required. Third-party reviewed.

LLZ Device Classification - Class 2, Special Controls

Product Code LLZ System, Image Processing, Radiological
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 892.2050
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Radiology devices follow this clearance model.

Regulatory Consultant

Underwriters Laboratories, Inc.
MARC M MOUSER

The regulatory consultant manages the 510(k) submission process on behalf of the applicant - coordinating technical documentation, predicate strategy and FDA communications. Identifying the consultant behind a submission is a key signal for competitive regulatory intelligence.

Regulatory Peers - LLZ System, Image Processing, Radiological

All 2282
Devices cleared under the same product code (LLZ) and FDA review panel - the closest regulatory comparables to K061305.
CENTRICITY AW SUITE OPTION
K061372 · Ge Healthcare Information Technologies · May 2006
QLAB QUANTIFICATION SOFTWARE
K061396 · Philips Ultrasound, Inc. · May 2006
MEDICAL DISPLAY, MODELS MDM 1900-1NG AND MDM 1900-1NR
K061303 · Chi Lin Technology Co., Ltd. · May 2006
VOXAR 3D ENTERPRISE WITH CARDIAMETRIX
K061326 · Barcoview Mis Edinburgh · May 2006
3MATIC
K060950 · Materialise NV · May 2006
MIM 4.0 (NEURO
K060816 · Mimvista Corp. · May 2006