Cleared Traditional

K061606 - DEFIBRILLATOR CABLE TESTER, MODEL DT2200

K061606 is an FDA 510(k) clearance for DEFIBRILLATOR CABLE TESTER, manufactured by Medical Devices/Padpro, Inc.. The device is a Class 2 Cardiovascular device with product code DRG cleared through the Traditional 510(k) pathway after a 12-day FDA review.

Download Printable Device Report (PDF) Official FDA 510(k) Summary (PDF)
Optimized for regulatory review, auditing and printing
Jun 2006
Decision
12d
Days
Class 2
Risk

K061606 is an FDA 510(k) clearance for the DEFIBRILLATOR CABLE TESTER, MODEL DT2200. Classified as Transmitters And Receivers, Physiological Signal, Radiofrequency (product code DRG), Class II - Special Controls.

Submitted by Medical Devices/Padpro, Inc. (Deer Field, US). The FDA issued a Cleared decision on June 21, 2006 after a review of 12 days - a notably fast clearance cycle.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.2910 - the FDA cardiovascular device oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

FDA 510(k) Submission Details - K061606

510(k) Number K061606 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received June 09, 2006
Decision Date June 21, 2006
Days to Decision 12 days
Submission Type Traditional
Review Panel Cardiovascular (CV)
Summary Summary PDF
Third-party Review Yes - reviewed by an FDA-accredited third party
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
113d faster than avg
Panel avg: 125d · This submission: 12d
Pathway characteristics
Predicate-based equivalence. No clinical trials required. Third-party reviewed.

DRG Device Classification - Class 2, Special Controls

Product Code DRG Transmitters And Receivers, Physiological Signal, Radiofrequency
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.2910
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Consultant

Regulatory Technology Services, LLC
MARK JOB

The regulatory consultant manages the 510(k) submission process on behalf of the applicant - coordinating technical documentation, predicate strategy and FDA communications. Identifying the consultant behind a submission is a key signal for competitive regulatory intelligence.

Regulatory Peers - DRG Transmitters And Receivers, Physiological Signal, Radiofrequency

All 189
Devices cleared under the same product code (DRG) and FDA review panel - the closest regulatory comparables to K061606.
CONFIDANT 2.0
K062215 · Confidant, Inc. · Oct 2006
DLM112 DAYLINK MONITOR
K062304 · Rtx Healthcare A/S · Sep 2006
MEDIC4ALL TELEMEDICINE SYSTEM VMS-01
K061502 · Medic4all (Israel) , Ltd. · Sep 2006
GENESIS OTC MONITOR
K061087 · Honeywell Hommed, LLC · Jun 2006
SENTRY OTC MONITOR
K061088 · Honeywell Hommed, LLC · Jun 2006
TELEPHONE BASED BL HEALTHCARE REMOTE CARE MANAGEMENT SYSTEM (RCMS)
K052608 · Bl Healthcare, Inc. · Feb 2006