Cleared Special

K061743 - VENOUS HARDSHELL CARDIOTOMY RESERVOIR W/SAFELINE COATING, MODEL BSQ-VHK 2000 (FDA 510(k) Clearance)

Also includes:
VACUUM TIGHT, MODEL BSQ-VHK 2001

Class II Cardiovascular device cleared through the Special 510(k) pathway - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Jul 2006
Decision
30d
Days
Class 2
Risk

K061743 is an FDA 510(k) clearance for the VENOUS HARDSHELL CARDIOTOMY RESERVOIR W/SAFELINE COATING, MODEL BSQ-VHK 2000. Classified as Reservoir, Blood, Cardiopulmonary Bypass (product code DTN), Class II - Special Controls.

Submitted by Maquet Cardiopulmonary, AG (Hirrlingen, DE). The FDA issued a Cleared decision on July 21, 2006 after a review of 30 days - a notably fast clearance cycle.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.4400 - the FDA cardiovascular device oversight framework. As a Special 510(k), this submission covers a manufacturer modification to an existing cleared device rather than a new device introduction.

Device pattern: Iterative device modification. Low regulatory complexity profile. This Special 510(k) clearance confirms that the manufacturer's modifications remained within the established regulatory envelope of the original cleared device.

View all Maquet Cardiopulmonary, AG devices

Submission Details

510(k) Number K061743 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received June 21, 2006
Decision Date July 21, 2006
Days to Decision 30 days
Submission Type Special
Review Panel Cardiovascular (CV)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
95d faster than avg
Panel avg: 125d · This submission: 30d
Pathway characteristics
Modification to existing cleared device.

Device Classification

Product Code DTN Reservoir, Blood, Cardiopulmonary Bypass
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.4400
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - DTN Reservoir, Blood, Cardiopulmonary Bypass

All 168
Devices cleared under the same product code (DTN) and FDA review panel - the closest regulatory comparables to K061743.
Inspire HCR and HCR DUAL cardiotomy reservoirs
K251783 · Sorin Group Italia S.R.L. · Dec 2025
Quantum Perfusion Hybrid System
K241206 · Spectrum Medical S.R.L. · Jul 2024
MVR™ Venous Reservoir Bag 800 mL
K241053 · Medtronic Cardiac Surgery · May 2024
BMR 1900 PHISIO
K223361 · Sorin Group Italia S.R.L. · Jun 2023