REFLEXION SPIRAL VARIABLE RADIUS CATHETER, MODEL 402804 (K062251) - FDA 510(k) Clearance

Class II Cardiovascular device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Oct 2006
Decision
78d
Days
Class 2
Risk

K062251 is an FDA 510(k) clearance for the REFLEXION SPIRAL VARIABLE RADIUS CATHETER, MODEL 402804. Classified as Catheter, Electrode Recording, Or Probe, Electrode Recording (product code DRF), Class II - Special Controls.

Submitted by St Jude Medical (Minnetonka, US). The FDA issued a Cleared decision on October 20, 2006 after a review of 78 days - a notably fast clearance cycle.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.1220 - the FDA cardiovascular device oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all St Jude Medical devices

Submission Details

510(k) Number K062251 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received August 03, 2006
Decision Date October 20, 2006
Days to Decision 78 days
Submission Type Traditional
Review Panel Cardiovascular (CV)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
47d faster than avg
Panel avg: 125d · This submission: 78d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code DRF Catheter, Electrode Recording, Or Probe, Electrode Recording
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.1220
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - DRF Catheter, Electrode Recording, Or Probe, Electrode Recording

All 50
Devices cleared under the same product code (DRF) and FDA review panel - the closest regulatory comparables to K062251.
Achieve ST Mapping Catheter, Catheter Connecting Cable
K153139 · Medtronic, Inc. · May 2016
RADIA STEERABLE DIAGNOSTIC CATHETER
K091370 · C.R. Bard, Inc. · Jun 2009
BLAZER DX-20 DIAGNOSTIC CATHETER
K081576 · Boston Scientific Corp · Feb 2009
EN CIRCLR AL ADJUSTABLE LOOP MAPPING CATHETER MODELS, 1045AL1, 1045AL2, 1060AL1, 1060AL2
K033050 · Medtronic Vascular · Mar 2004
ORBITER PV DIAGNOSTIC ELECTRODE CATHETER, MODELS 320100 & 320110
K030627 · C.R. Bard, Inc. · Oct 2003
CORDIS 13F CATHETER SHEATH INTRODUCER
K000753 · Cordis Corp. · Apr 2000