Cleared Special

K071058 - MULTIPLE PATIENT RECEIVER

K071058 is an FDA 510(k) clearance for MULTIPLE PATIENT RECEIVER, manufactured by Nihon Kohden America, Inc.. The device is a Class 2 Cardiovascular device with product code DRG cleared through the Special 510(k) pathway after a 74-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Jun 2007
Decision
74d
Days
Class 2
Risk

K071058 is an FDA 510(k) clearance for the MULTIPLE PATIENT RECEIVER, MODEL ORG-9700A. Classified as Transmitters And Receivers, Physiological Signal, Radiofrequency (product code DRG), Class II - Special Controls.

Submitted by Nihon Kohden America, Inc. (Foothill, US). The FDA issued a Cleared decision on June 29, 2007 after a review of 74 days - a notably fast clearance cycle.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.2910 - the FDA cardiovascular device oversight framework. As a Special 510(k), this submission covers a manufacturer modification to an existing cleared device rather than a new device introduction.

Device pattern: Iterative device modification. Low regulatory complexity profile. This Special 510(k) clearance confirms that the manufacturer's modifications remained within the established regulatory envelope of the original cleared device.

View all Nihon Kohden America, Inc. devices

FDA 510(k) Submission Details - K071058

510(k) Number K071058 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received April 16, 2007
Decision Date June 29, 2007
Days to Decision 74 days
Submission Type Special
Review Panel Cardiovascular (CV)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
51d faster than avg
Panel avg: 125d · This submission: 74d
Pathway characteristics
Modification to existing cleared device.

DRG Device Classification - Class 2, Special Controls

Product Code DRG Transmitters And Receivers, Physiological Signal, Radiofrequency
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.2910
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - DRG Transmitters And Receivers, Physiological Signal, Radiofrequency

All 73
Devices cleared under the same product code (DRG) and FDA review panel - the closest regulatory comparables to K071058.
HOSPIRA VITAL SIGNS WIRELESS MONITORING SYSTEM
K090610 · Hospira, Inc. · Mar 2009
FORA TELEHEALTH SYSTEM
K083046 · Taidoc Technology Corporation · Jan 2009
MOTIVA MONITOR DEVICE CONNECTIVITY, MODEL# 453564036921
K071564 · Philips Medical Systems · Aug 2007
THE PHILIPS MP20, MP30, MP40, MP50, MP60, MP70, AND MP90 INTELLIVUE PATIENT MONITORS, WITH 802.11 WIRELESS LAN
K052961 · Philips Medical Systems · Nov 2005
THE M3810A PHILIPS TELEMONITORING SYSTEM WITH M3812B TELESTATION (M310A/12B)
K023749 · Philips Medical Systems · Nov 2002
MODIFICATION OF: PHYSIOLOGICAL SIGNAL TRANSMITTER AND RECEIVER, MODEL 3810A
K993169 · Hewlett-Packard Co. · Dec 1999