Cleared Traditional

DIGITAL PULSE OXIMETER, MODEL 7500FO (K071415) - FDA 510(k) Clearance

Class II Anesthesiology device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Aug 2007
Decision
79d
Days
Class 2
Risk

K071415 is an FDA 510(k) clearance for the DIGITAL PULSE OXIMETER, MODEL 7500FO. Classified as Oximeter (product code DQA), Class II - Special Controls.

Submitted by Nonin Medical, Inc. (Plymouth, US). The FDA issued a Cleared decision on August 8, 2007 after a review of 79 days - a notably fast clearance cycle.

This device falls under the Anesthesiology FDA review panel, regulated under 21 CFR 870.2700 - the FDA anesthesiology and respiratory device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all Nonin Medical, Inc. devices

Submission Details

510(k) Number K071415 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received May 21, 2007
Decision Date August 08, 2007
Days to Decision 79 days
Submission Type Traditional
Review Panel Anesthesiology (AN)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
61d faster than avg
Panel avg: 140d · This submission: 79d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code DQA Oximeter
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.2700
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Anesthesiology devices follow this clearance model.

Regulatory Peers - DQA Oximeter

All 176
Devices cleared under the same product code (DQA) and FDA review panel - the closest regulatory comparables to K071415.
N-600X WITH SPD, OXIMAX N-600X
K083325 · Covidien · Mar 2009
PM-60 PULSE OXIMETER
K072581 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Jan 2008
PM-50 PULSE OXIMETER AND VS-800 VITAL SIGNS MONITOR
K072235 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Oct 2007
PULSE OXIMETER, MODEL PM-50
K061442 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Sep 2006
PM-50 PULSE OXIMETER
K052693 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Mar 2006
DATEX-OHMEDA S/5 NELLCOR COMPATIBLE SATURATION MODULE, E-NSAT
K052755 · Ge Healthcare · Oct 2005