K080319 - KD-591 FULLY AUTOMATIC ELECTRONIC BLOOD...

K080319 is the FDA 510(k) clearance for KD-591 FULLY AUTOMATIC ELECTRONIC BLOOD... by Andon Health Co, Ltd.. It is a Class 2 Cardiovascular device (product code DXN) cleared through the Traditional 510(k) pathway after a 147-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Jul 2008
Decision
147d
Days
Class 2
Risk

K080319 is an FDA 510(k) clearance for the KD-591 FULLY AUTOMATIC ELECTRONIC BLOOD PRESSURE MONITOR. Classified as System, Measurement, Blood-pressure, Non-invasive (product code DXN), Class II - Special Controls.

Submitted by Andon Health Co, Ltd. (Tiajin, CN). The FDA issued a Cleared decision on July 2, 2008 after a review of 147 days - within the typical 510(k) review window.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.1130 - the FDA cardiovascular device oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Standard predicate reliance. This clearance follows a standard predicate-based equivalence path within the Cardiovascular review framework, consistent with the majority of Class II 510(k) submissions.

View all Andon Health Co, Ltd. devices

Submission Details

510(k) Number K080319 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received February 06, 2008
Decision Date July 02, 2008
Days to Decision 147 days
Submission Type Traditional
Review Panel Cardiovascular (CV)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
22d slower than avg
Panel avg: 125d · This submission: 147d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code DXN System, Measurement, Blood-pressure, Non-invasive
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.1130
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - DXN System, Measurement, Blood-pressure, Non-invasive

All 500
Devices cleared under the same product code (DXN) and FDA review panel - the closest regulatory comparables to K080319.
MICROLIFE UPPER ARM AUTOMATIC DIGITAL BLOOD PRESSURE MONITOR, MODELWATCHBP OFFICE (TWIN200).
K082357 · Microlife Intellectual Property GmbH · Oct 2008
HEM-9000AI
K081654 · Omron Healthcare, Inc. · Oct 2008
KD-391 SEMI AUTOMATIC ELECTRONIC BLOOD PRESSURE MONITOR
K080326 · Andon Health Co, Ltd. · Jul 2008
CLEVER TD-3026 DIGITAL WRIST BLOOD PRESSURE MONITOR, MODEL TD-3026
K073445 · Taidoc Technology Corporation · Apr 2008
1500 PRO
K080289 · Omron Healthcare, Inc. · Feb 2008
MICROLIFE UPPER ARM AUTOMATIC DIGITAL BLOOD PRESSURE MONITOR, MODEL WATCHBP HOME (BP3MX1-1)
K073198 · Microlife Intellectual Property GmbH · Jan 2008