Cleared Traditional

K082194 - LAURIMED PERCUTANEOUS DISCECTOMY SYSTEM, MODEL FG-000002

K082194 is an FDA 510(k) clearance for LAURIMED PERCUTANEOUS DISCECTOMY SYSTEM, manufactured by Laurimed, LLC. The device is a Class 2 Orthopedic device with product code HRX cleared through the Traditional 510(k) pathway after a 24-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Aug 2008
Decision
24d
Days
Class 2
Risk

K082194 is an FDA 510(k) clearance for the LAURIMED PERCUTANEOUS DISCECTOMY SYSTEM, MODEL FG-000002. Classified as Arthroscope (product code HRX), Class II - Special Controls.

Submitted by Laurimed, LLC (Redwood City, US). The FDA issued a Cleared decision on August 28, 2008 after a review of 24 days - a notably fast clearance cycle.

This device falls under the Orthopedic FDA review panel, regulated under 21 CFR 888.1100 - the FDA orthopedic device regulatory framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all Laurimed, LLC devices

FDA 510(k) Submission Details - K082194

510(k) Number K082194 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received August 04, 2008
Decision Date August 28, 2008
Days to Decision 24 days
Submission Type Traditional
Review Panel Orthopedic (OR)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
98d faster than avg
Panel avg: 122d · This submission: 24d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

HRX Device Classification - Class 2, Special Controls

Product Code HRX Arthroscope
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 888.1100
Definition Validated Reprocessing Instructions And Reprocessing Validation Data For This Device Type Must Be Included In A 510(k) Submission If The Device Is Reusable And Has Specific Design Features (please Refer To Table 2 Of 82 Fr 26807, Available At Https://www.gpo.gov/fdsys/pkg/fr-2017-06-09/pdf/2017-12007.pdf).
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Orthopedic devices follow this clearance model.

Regulatory Peers - HRX Arthroscope

All 548
Devices cleared under the same product code (HRX) and FDA review panel - the closest regulatory comparables to K082194.
TIGER DISCECTOMY DEVICE
K081240 · Spinal Devices, LLC · Feb 2009
VISIONSENSE STEREOSCOPIC VISION SYSTEM
K082355 · Visionsense, Ltd. · Dec 2008
SURGVIEW INTEGRATED VISUALIZATION SYSTEM
K082293 · Biovision Technologies, LLC · Sep 2008
SPINEVU ENDOSCOPIC SPINE SYSTEM (SESS), SPINEVU MINISCOPE
K081051 · Spine View, Inc. · Aug 2008
SOPRO 670 ARTHROSCOPIC PUMP
K080122 · Sopro · Jul 2008
POWER DRIVE ART1 2304 WITH MOTOR HANDLES, TOOLS AND ACCESSORIES
K080617 · Richard Wolf Medical Instruments Corp. · Jun 2008