Cleared Traditional

K112542 - YOMURA SAFETY I.V. CATHETER

K112542 is an FDA 510(k) clearance for YOMURA SAFETY I.V. CATHETER, manufactured by Yomura Technologies, Inc.. The device is a Class 2 General Hospital device with product code FOZ cleared through the Traditional 510(k) pathway after a 160-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Feb 2012
Decision
160d
Days
Class 2
Risk

K112542 is an FDA 510(k) clearance for the YOMURA SAFETY I.V. CATHETER. Classified as Catheter, Intravascular, Therapeutic, Short-term Less Than 30 Days (product code FOZ), Class II - Special Controls.

Submitted by Yomura Technologies, Inc. (New Taipei City, TW). The FDA issued a Cleared decision on February 8, 2012 after a review of 160 days - an extended review cycle.

This device falls under the General Hospital FDA review panel, regulated under 21 CFR 880.5200 - the FDA general hospital device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Standard predicate reliance. This clearance follows a standard predicate-based equivalence path within the General Hospital review framework, consistent with the majority of Class II 510(k) submissions.

View all Yomura Technologies, Inc. devices

FDA 510(k) Submission Details - K112542

510(k) Number K112542 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received September 01, 2011
Decision Date February 08, 2012
Days to Decision 160 days
Submission Type Traditional
Review Panel General Hospital (HO)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
31d slower than avg
Panel avg: 129d · This submission: 160d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

FOZ Device Classification - Class 2, Special Controls

Product Code FOZ Catheter, Intravascular, Therapeutic, Short-term Less Than 30 Days
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 880.5200
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most General Hospital devices follow this clearance model.

Regulatory Peers - FOZ Catheter, Intravascular, Therapeutic, Short-term Less Than 30 Days

All 300
Devices cleared under the same product code (FOZ) and FDA review panel - the closest regulatory comparables to K112542.
MULTI-MED CENTRAL VENOUS CATHETERS (CVCS), WITH AND WITHOUT HEPARIN VANTEX CENTRAL VENOUS CATHETERS (CVCS), WITH HEPARIN
K113565 · Edwards Lifesciences, LLC · May 2012
VIAVALVE SAFETY IV CATHETER
K113700 · Smiths Medical Asd, Inc. · Mar 2012
SAFETOUCH PSV WINGED INFUSION SET, AND SET WITH FILTER
K113429 · Nipro Medical Corporation · Mar 2012
BD INSYTE AUTOGUARD BC
K110443 · Becton, Dickinson & CO · Jul 2011
BD NEXIVA CLOSED IV CATHETER SYSTEM
K102520 · Becton Dickinson Infusion Therapy Systems, Inc. · Jan 2011
BD INTIMA II CLOSED IV CATHETER
K100775 · Becton Dickinson Infusion Therapy Systems, Inc. · Jun 2010