Cleared Traditional

K131126 - OPTI CCA-TS2 (FDA 510(k) Clearance)

Class II Chemistry device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Aug 2013
Decision
122d
Days
Class 2
Risk

K131126 is an FDA 510(k) clearance for the OPTI CCA-TS2. Classified as Electrode Measurement, Blood-gases (pco2, Po2) And Blood Ph (product code CHL), Class II - Special Controls.

Submitted by Opti Medical Systems, Inc. (Roswell, US). The FDA issued a Cleared decision on August 22, 2013 after a review of 122 days - within the typical 510(k) review window.

This device falls under the Chemistry FDA review panel, regulated under 21 CFR 862.1120 - the FDA in vitro diagnostics and chemistry framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Standard predicate reliance. This clearance follows a standard predicate-based equivalence path within the Chemistry review framework, consistent with the majority of Class II 510(k) submissions.

View all Opti Medical Systems, Inc. devices

Submission Details

510(k) Number K131126 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received April 22, 2013
Decision Date August 22, 2013
Days to Decision 122 days
Submission Type Traditional
Review Panel Chemistry (CH)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
34d slower than avg
Panel avg: 88d · This submission: 122d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code CHL Electrode Measurement, Blood-gases (pco2, Po2) And Blood Ph
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 862.1120
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Chemistry devices follow this clearance model.

Regulatory Peers - CHL Electrode Measurement, Blood-gases (pco2, Po2) And Blood Ph

All 187
Devices cleared under the same product code (CHL) and FDA review panel - the closest regulatory comparables to K131126.
ABL90 FLEX PLUS System, safeCLINITUBES
K252207 · Radiometer Medicals Aps · Apr 2026
i-STAT CG4+ cartridge with the i-STAT 1 System
K244014 · Abbott Point of Care, Inc. · May 2025
ABL90 FLEX PLUS System
K240998 · Radiometer Medicals Aps · Dec 2024
i-STAT CG8+ cartridge with the i-STAT 1 System
K230285 · Abbott Point of Care, Inc. · Oct 2023
Stat Profile Prime Plus Analyzer System
K221900 · Nova Biomedical Corporation · Sep 2023
i-STAT G3+ cartridge with the i-STAT 1 System
K223857 · Abbott Point of Care, Inc. · Sep 2023