Cleared Traditional

K131892 - EV1000 CLINICAL PLATFORM

K131892 is an FDA 510(k) clearance for EV1000 CLINICAL PLATFORM, manufactured by Edwards Lifesciences, LLC. The device is a Class 2 Cardiovascular device with product code DXG cleared through the Traditional 510(k) pathway after a 331-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
May 2014
Decision
331d
Days
Class 2
Risk

K131892 is an FDA 510(k) clearance for the EV1000 CLINICAL PLATFORM. Classified as Computer, Diagnostic, Pre-programmed, Single-function (product code DXG), Class II - Special Controls.

Submitted by Edwards Lifesciences, LLC (Irvine, US). The FDA issued a Cleared decision on May 22, 2014 after a review of 331 days - an unusually long review period, suggesting complex equivalence evaluation.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.1435 - the FDA cardiovascular device oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Elevated predicate reliance profile. This clearance follows a standard predicate-based equivalence path within the Cardiovascular review framework, consistent with the majority of Class II 510(k) submissions.

View all Edwards Lifesciences, LLC devices

FDA 510(k) Submission Details - K131892

510(k) Number K131892 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received June 25, 2013
Decision Date May 22, 2014
Days to Decision 331 days
Submission Type Traditional
Review Panel Cardiovascular (CV)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
206d slower than avg
Panel avg: 125d · This submission: 331d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

DXG Device Classification - Class 2, Special Controls

Product Code DXG Computer, Diagnostic, Pre-programmed, Single-function
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.1435
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - DXG Computer, Diagnostic, Pre-programmed, Single-function

All 85
Devices cleared under the same product code (DXG) and FDA review panel - the closest regulatory comparables to K131892.
Argos
K181372 · Retia Medical, LLC · Dec 2018
PulsioFlex Monitoring System
K172259 · Pulsion Medical Systems SE · Jan 2018
VIGILEO ARTERIAL PRESSURE CARDIAC OUTPUT/OXIMETRY MONITOR
K131588 · Edwards Lifesciences, LLC · May 2014
E-PICCO CONTINUOUS CARDIAC OUTPUT MODULE AND ACCESSORIES
K132528 · GE Healthcare Finland Oy · Jan 2014
VIGILEO ARTERIAL PRESSURE CARDIAC OUTPUT / OXIMETRY MONITOR
K103094 · Edwards Lifesciences, LLC · May 2011
EV1000 PLATFORM MODEL: EV1000A, EV1000DB, EV1000M
K100709 · Edwards Lifesciences, LLC · Dec 2010