Cleared Traditional

Beamer AVEO Electrosurgical Generator, Beamer AVEO Argon Module, Beamer AVEO Cart, Beamer AVEO Wired Foot Pedal, Beamer AVEO Argon Pressure Reducer (K214058) - FDA 510(k) Clearance

Class II General & Plastic Surgery device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Aug 2022
Decision
242d
Days
Class 2
Risk

K214058 is an FDA 510(k) clearance for the Beamer AVEO Electrosurgical Generator, Beamer AVEO Argon Module, Beamer AVEO .... Classified as Electrosurgical, Cutting & Coagulation & Accessories within the GEI classification (a category for electrosurgical cutting and coagulation devices), Class II - Special Controls.

Submitted by Conmed Corporation (Utica, US). The FDA issued a Cleared decision on August 26, 2022 after a review of 242 days - an extended review cycle.

This device falls under the General & Plastic Surgery FDA review panel, regulated under 21 CFR 878.4400 - the FDA general and plastic surgery device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Standard predicate reliance. This clearance follows a standard predicate-based equivalence path within the General & Plastic Surgery review framework, consistent with the majority of Class II 510(k) submissions.

View all Conmed Corporation devices

Submission Details

510(k) Number K214058 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received December 27, 2021
Decision Date August 26, 2022
Days to Decision 242 days
Submission Type Traditional
Review Panel General & Plastic Surgery (SU)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
127d slower than avg
Panel avg: 115d · This submission: 242d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code GEI Electrosurgical, Cutting & Coagulation & Accessories
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 878.4400
Definition Validated Reprocessing Instructions And Reprocessing Validation Data For This Device Type Must Be Included In A 510(k) Submission If The Device Is Reusable And Has Specific Design Features (please Refer To Table 2 Of 82 Fr 26807, Available At Https://www.gpo.gov/fdsys/pkg/fr-2017-06-09/pdf/2017-12007.pdf).
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most General & Plastic Surgery devices follow this clearance model.

Regulatory Peers - GEI Electrosurgical, Cutting & Coagulation & Accessories

All 694
Devices cleared under the same product code (GEI) and FDA review panel - the closest regulatory comparables to K214058.
Mygen M-3004 RF Generator M-3004
K221277 · RF Medical Co., Ltd. · Sep 2022
CellFX System
K222075 · Pulse Biosciences, Inc. · Sep 2022
Ambient HipVac 50 Wand with Integrated Finger Switches, RF20000 COBLATION System, WEREWOLF COBLATION System, WEREWOLF+ COBLATION System
K220563 · ArthroCare Corporation · Sep 2022
CellFX® System
K221671 · Pulse Biosciences, Inc. · Aug 2022
RhinAer® Stylus (FG1393)
K221907 · Aerin Medical, Inc. · Jul 2022
Beamer AVEO FILTER INTEGRATED ARGON PROBE 1.8mm x 160 cm, Beamer AVEO FILTER INTEGRATED ARGON PROBE 1.8 mm X 320 cm, Beamer AVEO FILTER INTEGRATED ARGON PROBE 2.3 mm X 230 cm, Beamer AVEO FILTER INTEGRATED ARGON PROBE 2.3 mm x 320 cm, Beamer AVEO FILTER INTEGRATED ARGON SIDEFIRE PROBE 2.3 mm x 230 cm
K221945 · Conmed Corporation · Jul 2022