Cleared Traditional

K252498 - Digital Color Doppler Ultrasound System (X11 Exp/X11 Elite/X11 Pro/X11 Plus/X11 Super/X11 Senior/X11/E11/E11 Pro/E11 Plus/E11 Elite/X11T/X11U/X11R/X11i/X11s/E11T/E11i/E11s/XR1/XR2/ XR3/ER1/ER2/ER3/X10 Exp/X10 Elite/X10 Pro/X10 Plus/X10 Super/X10 Senior/X10/X10T/X10U/ X10R/X10i/X10s/E10/E10 Pro/E10 Plus/E10T/E10i/E10s/SU11A EXP/SU11A PRO/SU11A AD/ SU11A CU/SU11B EXP/SU11B PRO/SU11B AD/SU11B CU/SU11C EXP/SU11C PRO/SU11C AD/ SU11C CU)

K252498 is an FDA 510(k) clearance for Digital Color Doppler Ultrasound System..., manufactured by Sonoscape Medical Corp.. The device is a Class 2 Radiology device with product code IYN cleared through the Traditional 510(k) pathway after a 119-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Dec 2025
Decision
119d
Days
Class 2
Risk

K252498 is an FDA 510(k) clearance for the Digital Color Doppler Ultrasound System (X11 Exp/X11 Elite/X11 Pro/X11 Plus/X.... Classified as System, Imaging, Pulsed Doppler, Ultrasonic within the IYN classification (a category covering pulsed Doppler and ultrasound imaging systems), Class II - Special Controls.

Submitted by Sonoscape Medical Corp. (Shenzhen, CN). The FDA issued a Cleared decision on December 5, 2025 after a review of 119 days - within the typical 510(k) review window.

This device falls under the Radiology FDA review panel, regulated under 21 CFR 892.1550 - the FDA radiology and imaging software oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Standard predicate reliance. This clearance follows a standard predicate-based equivalence path within the Radiology review framework, consistent with the majority of Class II 510(k) submissions.

View all Sonoscape Medical Corp. devices

FDA 510(k) Submission Details - K252498

510(k) Number K252498 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received August 08, 2025
Decision Date December 05, 2025
Days to Decision 119 days
Submission Type Traditional
Review Panel Radiology (RA)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
12d slower than avg
Panel avg: 107d · This submission: 119d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

IYN Device Classification - Class 2, Special Controls

Product Code IYN System, Imaging, Pulsed Doppler, Ultrasonic
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 892.1550
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Radiology devices follow this clearance model.

Regulatory Peers - IYN System, Imaging, Pulsed Doppler, Ultrasonic

All 1084
Devices cleared under the same product code (IYN) and FDA review panel - the closest regulatory comparables to K252498.
Diagnostic Ultrasound System (Nano C5, Nano C5 EXP, Nano L12, and Nano L12 EXP)
K251268 · Edan Instruments, Inc. · Dec 2025
BioticsAI
K250959 · Bioticsai, Inc. · Dec 2025
Lumify Diagnostic Ultrasound System
K252557 · Philips Ultrasound, LLC · Dec 2025
ASUS Ultrasound Imaging System (LU800 series)
K250791 · Asustek Computer, Inc. · Dec 2025
Hepatus 7/Hepatus 6/Hepatus 5/Hepatus 7S/Hepatus 6S/Hepatus 5S/Hepatus7T/Hepatus 6T/Hepatus 5T/Fibrous 7/Fibrous 6/Fibrous 5 Diagnostic UltrasoundSystem
K251601 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Dec 2025
7600 Ultrasound System (MyLabC25)
K253310 · Esaote, S.P.A. · Nov 2025