Cleared Traditional

ATRIAL J TEMPORARY PACING ELECTRODESS (K821333) - FDA 510(k) Clearance

Class II Cardiovascular device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Jun 1982
Decision
28d
Days
Class 2
Risk

K821333 is an FDA 510(k) clearance for the ATRIAL J TEMPORARY PACING ELECTRODESS. Classified as Electrode, Pacemaker, Temporary (product code LDF), Class II - Special Controls.

Submitted by Medics Instrument Corp. (Mchenry, US). The FDA issued a Cleared decision on June 2, 1982 after a review of 28 days - a notably fast clearance cycle.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.3680 - the FDA cardiovascular device oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all Medics Instrument Corp. devices

Submission Details

510(k) Number K821333 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received May 05, 1982
Decision Date June 02, 1982
Days to Decision 28 days
Submission Type Traditional
Review Panel Cardiovascular (CV)
Summary -
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
97d faster than avg
Panel avg: 125d · This submission: 28d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code LDF Electrode, Pacemaker, Temporary
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.3680
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - LDF Electrode, Pacemaker, Temporary

All 47
Devices cleared under the same product code (LDF) and FDA review panel - the closest regulatory comparables to K821333.
LUMELEC ELECTRODE CATHETER
K834416 · Cordis Corp. · Apr 1984
EPCOR MULTIELECTRODE TEMP. PERVENOUS
K832561 · Cordis Corp. · Oct 1983
USCI TEMP. ATRIO-VENTRICULAR ELECTRODE
K830094 · C.R. Bard, Inc. · Feb 1983
ETHICON* TEMP. CARDIAC PACING WIRE
K813138 · Ethicon, Inc. · Dec 1981
MODEL 5867-12 BIPOLAR LOW-PROFILE LEAD
K812725 · Medtronic Vascular · Nov 1981
TEMPORARY PERVENOUS J-ATRIAL LEAD
K812781 · Cordis Corp. · Oct 1981