Cleared Traditional

K885120 - ESI MODEL MS-103

K885120 is an FDA 510(k) clearance for ESI MODEL MS-103, manufactured by Electrical Systems Div.. The device is a Class 2 Neurology device with product code GZT cleared through the Traditional 510(k) pathway after a 403-day FDA review.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Jan 1990
Decision
403d
Days
Class 2
Risk

K885120 is an FDA 510(k) clearance for the ESI MODEL MS-103. Classified as Retractor, Self-retaining, For Neurosurgery (product code GZT), Class II - Special Controls.

Submitted by Electrical Systems Div. (San Antonio, US). The FDA issued a Cleared decision on January 19, 1990 after a review of 403 days - an unusually long review period, suggesting complex equivalence evaluation.

This device falls under the Neurology FDA review panel, regulated under 21 CFR 882.4800 - the FDA neurology device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: High-complexity regulatory submission. Elevated predicate reliance profile. The extended review timeline suggests the FDA required additional documentation before confirming substantial equivalence - a pattern common in complex or first-of-kind Neurology submissions.

FDA 510(k) Submission Details - K885120

510(k) Number K885120 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received December 12, 1988
Decision Date January 19, 1990
Days to Decision 403 days
Submission Type Traditional
Review Panel Neurology (NE)
Summary -
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
254d slower than avg
Panel avg: 149d · This submission: 403d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

GZT Device Classification - Class 2, Special Controls

Product Code GZT Retractor, Self-retaining, For Neurosurgery
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 882.4800
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Neurology devices follow this clearance model.

Regulatory Peers - GZT Retractor, Self-retaining, For Neurosurgery

All 43
Devices cleared under the same product code (GZT) and FDA review panel - the closest regulatory comparables to K885120.
BLADES FOR SPINAL LAMINECTOMY RETRACTOR
K910621 · International Hospital Supply Co. · Apr 1991
ADSON-BECKMAN RETRACTOR, SPINAL
K905445 · A. Henniss · Jan 1991
NEUROSURGICAL HEADFRAME ACCESSORIES
K902517 · Sims Surgical, Inc. · Jul 1990
COMPASS(TM) STEREOTACTIC RETRACTOR SYSTEM
K896156 · Stereotactic Medical Systems, Inc. · Dec 1989
V. MUELLER RHOTON SELF-RETAINING BRAIN RETRACTOR
K895395 · Baxter Healthcare Corp · Oct 1989
MODIFIED MEMORY RETRACTOR ARM
K895537 · Medical Equipment Development Co., Inc. · Sep 1989