Cleared Traditional

K910646 - SUPERSERUM REAGENT (SSR) (FDA 510(k) Clearance)

Class II Chemistry device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
May 1991
Decision
86d
Days
Class 2
Risk

K910646 is an FDA 510(k) clearance for the SUPERSERUM REAGENT (SSR). Classified as Tubes, Vials, Systems, Serum Separators, Blood Collection (product code JKA), Class II - Special Controls.

Submitted by International Technidyne Corp. (Edison, US). The FDA issued a Cleared decision on May 10, 1991 after a review of 86 days - a notably fast clearance cycle.

This device falls under the Chemistry FDA review panel, regulated under 21 CFR 862.1675 - the FDA in vitro diagnostics and chemistry framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all International Technidyne Corp. devices

Submission Details

510(k) Number K910646 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received February 13, 1991
Decision Date May 10, 1991
Days to Decision 86 days
Submission Type Traditional
Review Panel Chemistry (CH)
Summary -
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
2d faster than avg
Panel avg: 88d · This submission: 86d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code JKA Tubes, Vials, Systems, Serum Separators, Blood Collection
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 862.1675
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Chemistry devices follow this clearance model.

Regulatory Peers - JKA Tubes, Vials, Systems, Serum Separators, Blood Collection

All 236
Devices cleared under the same product code (JKA) and FDA review panel - the closest regulatory comparables to K910646.
BD Preset™ and BD A-Line™ Arterial Blood Collection Syringes
K260128 · Becton, Dickinson and Company · Apr 2026
BD® MiniDraw™ Capillary Blood Collection System with BD® MiniDraw™ SST™ Capillary Blood Collection Tube
K252378 · Becton, Dickinson and Company · Apr 2026
BD Vacutainer® Safety-Lok™ Blood Collection Set
K252506 · Becton, Dickinson and Company · Apr 2026
BD Vacutainer® Plasma Separator Tubes (PST™), BD Vacutainer® Sodium Heparin Blood Collection Tubes
K252040 · Becton, Dickinson and Company · Mar 2026
Steripath® Flow™ Blood Collection System
K251812 · Magnolia Medical Technologies · Sep 2025
BD Vacutainer® Eclipse™ Blood Collection Needle
K243207 · Becton, Dickinson and Company · Jul 2025