Cleared Traditional

K944052 - RASCAL-II RESPIRATORY AND ANESTHETIC GAS MONITOR (FDA 510(k) Clearance)

Class II Anesthesiology device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Jul 1995
Decision
322d
Days
Class 2
Risk

K944052 is an FDA 510(k) clearance for the RASCAL-II RESPIRATORY AND ANESTHETIC GAS MONITOR. Classified as Analyzer, Gas, Carbon-dioxide, Gaseous-phase (product code CCK), Class II - Special Controls.

Submitted by Ohmeda Medical (Madison, US). The FDA issued a Cleared decision on July 7, 1995 after a review of 322 days - an unusually long review period, suggesting complex equivalence evaluation.

This device falls under the Anesthesiology FDA review panel, regulated under 21 CFR 868.1400 - the FDA anesthesiology and respiratory device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Standard predicate-based submission. Elevated predicate reliance profile. This clearance follows a standard predicate-based equivalence path within the Anesthesiology review framework, consistent with the majority of Class II 510(k) submissions.

View all Ohmeda Medical devices

Submission Details

510(k) Number K944052 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received August 19, 1994
Decision Date July 07, 1995
Days to Decision 322 days
Submission Type Traditional
Review Panel Anesthesiology (AN)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
183d slower than avg
Panel avg: 139d · This submission: 322d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code CCK Analyzer, Gas, Carbon-dioxide, Gaseous-phase
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 868.1400
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Anesthesiology devices follow this clearance model.

Regulatory Peers - CCK Analyzer, Gas, Carbon-dioxide, Gaseous-phase

All 304
Devices cleared under the same product code (CCK) and FDA review panel - the closest regulatory comparables to K944052.
Capnostream™35 Portable Respiratory Monitor (PM35MN)
K253030 · Covidien, LLC · May 2026
Medical Gas Analyzer (AG200)
K250148 · Prior Care Science Technology, Ltd. · Aug 2025
TG-980P CO2 Sensor Kit (TG-980P)
K243956 · Nihon Kohden Corporation · Jun 2025
0184 CO2 Sampling line
K251216 · Barbaras Development, Inc. · Jun 2025
AIM (N/A)
K240937 · Inventeur, LLC · Dec 2024
AirLife™ Open Et Oxygen Mask, AirLife™ Open Et+ Oxygen Mask
K230915 · Vyaire Medical, Inc. · Nov 2024