Cleared Traditional

CABLE HOLDER, SUCTION TUBE HOLDER (K971040) - FDA 510(k) Clearance

Class II General & Plastic Surgery device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Apr 1997
Decision
26d
Days
Class 2
Risk

K971040 is an FDA 510(k) clearance for the CABLE HOLDER, SUCTION TUBE HOLDER. Classified as Electrosurgical, Cutting & Coagulation & Accessories within the GEI classification (a category for electrosurgical cutting and coagulation devices), Class II - Special Controls.

Submitted by Contour Fabricators, Inc. (Grand Blanc, US). The FDA issued a Cleared decision on April 16, 1997 after a review of 26 days - a notably fast clearance cycle.

This device falls under the General & Plastic Surgery FDA review panel, regulated under 21 CFR 878.4400 - the FDA general and plastic surgery device framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all Contour Fabricators, Inc. devices

Submission Details

510(k) Number K971040 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received March 21, 1997
Decision Date April 16, 1997
Days to Decision 26 days
Submission Type Traditional
Review Panel General & Plastic Surgery (SU)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Regulatory Context
Review time vs. panel average
89d faster than avg
Panel avg: 115d · This submission: 26d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code GEI Electrosurgical, Cutting & Coagulation & Accessories
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 878.4400
Definition Validated Reprocessing Instructions And Reprocessing Validation Data For This Device Type Must Be Included In A 510(k) Submission If The Device Is Reusable And Has Specific Design Features (please Refer To Table 2 Of 82 Fr 26807, Available At Https://www.gpo.gov/fdsys/pkg/fr-2017-06-09/pdf/2017-12007.pdf).
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most General & Plastic Surgery devices follow this clearance model.

Regulatory Peers - GEI Electrosurgical, Cutting & Coagulation & Accessories

All 570
Devices cleared under the same product code (GEI) and FDA review panel - the closest regulatory comparables to K971040.
KARL STORZ MONOPOLAR COAGULATING ELECTRODES/ KARL STORZ MONOPOLAR COAGULATING NEEDLE ELECTRODES
K972497 · KARL STORZ Endoscopy-America, Inc. · Aug 1997
AESCULAP JET IRRIGATION SYSTEM
K971310 · Aesculap, Inc. · Jul 1997
3M UNIVERSAL ELECTROSURGICAL PAD SPLIT/SOLID(9130&9160)
K971446 · 3M Company · Jul 1997
AESCULAP MODULAR MONOPOLAR ELECTRODES
K970541 · Aesculap, Inc. · Mar 1997
MITEK ELECTROSURGICAL SYSTEM FOR ARTHROSCOPIC USE
K963783 · Ethicon, Inc. · Nov 1996
MIRROR FINISH BIPOLAR FORCEPS
K963499 · Johnson & Johnson Professionals, Inc. · Oct 1996