Cleared Traditional

CORDIS SUPER TORQUE MB ANGIOGRAPHIC CATHETER WITH RADIOPAQUE MARKER BANDS (K992347) - FDA 510(k) Clearance

Class II Cardiovascular device cleared through predicate-based substantial equivalence - typically does not require clinical trials.

Download Printable Device Report (PDF)
Optimized for regulatory review, auditing and printing
Oct 1999
Decision
86d
Days
Class 2
Risk

K992347 is an FDA 510(k) clearance for the CORDIS SUPER TORQUE MB ANGIOGRAPHIC CATHETER WITH RADIOPAQUE MARKER BANDS. Classified as Catheter, Intravascular, Diagnostic (product code DQO), Class II - Special Controls.

Submitted by Cordis Corp. (Warren, US). The FDA issued a Cleared decision on October 8, 1999 after a review of 86 days - a notably fast clearance cycle.

This device falls under the Cardiovascular FDA review panel, regulated under 21 CFR 870.1200 - the FDA cardiovascular device oversight framework. The Traditional 510(k) pathway establishes clearance through substantial equivalence to a legally marketed predicate device, without requiring clinical trial data.

Device pattern: Fast-track predicate clearance. Standard predicate reliance. The short review cycle indicates strong predicate alignment - the FDA found sufficient equivalence without extended technical review.

View all Cordis Corp. devices

Submission Details

510(k) Number K992347 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received July 14, 1999
Decision Date October 08, 1999
Days to Decision 86 days
Submission Type Traditional
Review Panel Cardiovascular (CV)
Summary Summary PDF
Third-party Review No - reviewed directly by FDA
Combination Product No
PCCP Authorized No
Regulatory Context
Review time vs. panel average
39d faster than avg
Panel avg: 125d · This submission: 86d
Pathway characteristics
Predicate-based equivalence. No clinical trials required.

Device Classification

Product Code DQO Catheter, Intravascular, Diagnostic
Device Class Class 2 - Special Controls
CFR Regulation 21 CFR 870.1200
What this classification means

Class II devices require demonstration of substantial equivalence to a legally marketed predicate device. This pathway does not require clinical trials - it relies on engineering equivalence and performance data. Most Cardiovascular devices follow this clearance model.

Regulatory Peers - DQO Catheter, Intravascular, Diagnostic

All 173
Devices cleared under the same product code (DQO) and FDA review panel - the closest regulatory comparables to K992347.
COOK PRESSURE MONITORING CATHETER
K002254 · Cook, Inc. · Mar 2001
TEMPO AQUA ANGIOGRAPHIC CATHETER
K000579 · Cordis Corp. · May 2000
MODIFICATION TO SOFTOUCH DIAGNOSTIC INTRAVASCULAR CAT
K000659 · Merit Medical Systems, Inc. · Mar 2000
RADIFOCUS OPTITORQUE
K992051 · Terumo Medical Corp. · Aug 1999
CORDIS TEMPO ANGIOGRAPHY CATHETER
K991673 · Cordis Corp. · May 1999
ENVY GUIDING CATHETER
K974774 · Cook, Inc. · Oct 1998